{"id":6041,"date":"2022-11-14T05:43:49","date_gmt":"2022-11-14T05:43:49","guid":{"rendered":"https:\/\/senslite.com.tw\/Home\/?page_id=6041"},"modified":"2022-11-14T05:43:52","modified_gmt":"2022-11-14T05:43:52","slug":"silicon-based-thermopile-ir-sensor","status":"publish","type":"page","link":"https:\/\/senslite.com.tw\/Home\/index.php\/silicon-based-thermopile-ir-sensor\/","title":{"rendered":"Silicon-Based Thermopile IR Sensor"},"content":{"rendered":"\n<p>Silicon -based Thermopile is designed for non-contact temperature measurement.  SL500-90 is a single -channel type thermopile sensor provided in chip form with small, low-noise, high sensitive.  It&#8217;s an ideal solution for forehead thermometer to use with an active area size of 0.196mm^2.<\/p>\n\n\n\n<p class=\"has-vivid-cyan-blue-color has-text-color has-medium-font-size\"><strong>Technical Specification<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"648\" src=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-1024x648.jpg\" alt=\"\" class=\"wp-image-6043\" srcset=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-1024x648.jpg 1024w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-300x190.jpg 300w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-768x486.jpg 768w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-700x443.jpg 700w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-410x259.jpg 410w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-100x63.jpg 100w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification-275x174.jpg 275w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_specification.jpg 1201w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1.jpg\" alt=\"\" class=\"wp-image-6044\" width=\"301\" height=\"297\" srcset=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1.jpg 766w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1-300x296.jpg 300w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1-700x690.jpg 700w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1-410x404.jpg 410w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1-100x99.jpg 100w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pad_Sensor_area-1-275x271.jpg 275w\" sizes=\"auto, (max-width: 301px) 100vw, 301px\" \/><figcaption>SL500-90 Thermopile Chip padding Diagram<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"979\" height=\"230\" src=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment.jpg\" alt=\"\" class=\"wp-image-6045\" srcset=\"https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment.jpg 979w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-300x70.jpg 300w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-768x180.jpg 768w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-700x164.jpg 700w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-410x96.jpg 410w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-100x23.jpg 100w, https:\/\/senslite.com.tw\/Home\/wp-content\/uploads\/2022\/11\/SL500_90_Pin_assignment-275x65.jpg 275w\" sizes=\"auto, (max-width: 979px) 100vw, 979px\" \/><figcaption><strong>SL500-90 Pin Definition<\/strong><\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Silicon -based Thermopile is designed for non-contact temperature measurement. SL500-90 is a single -channel type thermopile sensor provided in chip form with small, low-noise, high sensitive. It&#8217;s an ideal solution for forehead thermometer to use with an active area size of 0.196mm^2. Technical Specification<\/p>\n","protected":false},"author":1,"featured_media":6043,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6041","page","type-page","status-publish","has-post-thumbnail","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/pages\/6041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/comments?post=6041"}],"version-history":[{"count":1,"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/pages\/6041\/revisions"}],"predecessor-version":[{"id":6046,"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/pages\/6041\/revisions\/6046"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/media\/6043"}],"wp:attachment":[{"href":"https:\/\/senslite.com.tw\/Home\/index.php\/wp-json\/wp\/v2\/media?parent=6041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}